Features:
1.Segregated cold aisle air flow from hot aisle air flow.
2.Maximises cooling effect of cold aisle
3.Reduces workload of computer room air conditioning
4.Reduces energy cost
5.Reduces carbon footprint
6.Passive cooling versions
7.Active versions with automated panel opening for instances of fire
8.Totally integrated with cabinet infrastructure
9.Not connected to the building
10.Can be quickly installed
11.Easily relocated
12.CannonGuard remote management upgrades
13.Can be retrofitted to existing bays of enclosures with the use of customising kits
14.Within aisle lighting upgrades
Rack system
● 19" standard system
● Glass front door, 200 wide cold passage
● Back door glass door, 150 wide heat channel
● Cabinet bearing capacity is 1500KG
● A variety of wiring accessories inside the cabinet for easy routing
● 24" standard system
● The cold and hot channel is closed to guarantee the cooling effect and reduce PUE
The power distribution system
● High-performance UPS is optional
● Modular
● Rack type
● Support battery pack or battery cabinet
● Wiring module integrated UPS, input and output power distribution, air conditioning, lighting, monitoring power distribution
● Two - way ATS input is optional
●Support N,N+1,2N power supply system
The monitoring system
● Power supply circuit monitoring
● UPS monitoring, air conditioning monitoring
● Internal temperature and humidity monitoring
● Smoke sensor, optional fire opens cabinet door
● Large screen interface
● Integrated into BMS, third-party monitoring
Four Functional Features | Range Of Application |
Air supply scheme at the bottom ● Underfloor air supply upward ● Parallel air supply for air conditioning between columns ● Optional: 1200MM deep airtight cold or hot airway ● The number of cabinet can be adjusted flexibly according to customers' needs ● Optional lighting system and lighting rendering system ● Visualize both sliding doors or automatic sliding doors ● Optional access control access system ● Optional cabinet top cable level management system ● Optional tilting skylight, fire linkage management system | |
Horizontal air supply program ● Parallel air supply for air conditioning between columns ● Optional: 1200MM deep airtight cold or hot airway ● The number of cabinet can be adjusted flexibly according to customers' needs ● Optional lighting system and lighting rendering system ●Visualize both sliding doors or automatic sliding doors ● Optional access control access system ● Optional cabinet top cable level management system ● Optional tilting skylight, fire linkage management system |